Operation Guide | How to Test the Output Voltage of Transformer and IGBT Electrofusion Welders
WP20F
After switching on the machine, use the barcode scanner to scan the fitting's barcode.
Once the barcode has been scanned, the fitting parameters, such as the welding voltage, will be displayed on the screen. Check that the displayed voltage matches the voltage specified on the fitting.

Start the welding process.
Set the multimeter to the 750V AC voltage range. Then place the two multimeter probes against the two copper output terminals, respectively, to measure the output voltage.

Observe the multimeter reading and check whether it matches the voltage displayed on the machine. A deviation of ±0.5V is considered within the normal acceptable range.

WP20F Video
WP45K IGBT
After switching on the machine, use the barcode scanner to scan the fitting's barcode.
Once the barcode has been scanned, the fitting parameters, such as the welding voltage, will be displayed on the screen. Check that the displayed voltage matches the voltage specified on the fitting.

Start the welding process.
Set the multimeter to the 1000V DC voltage range. Then place the two multimeter probes against the two copper output terminals, respectively, to measure the output voltage.

Observe the multimeter reading and check whether it matches the voltage displayed on the machine. A deviation of ±0.5V is considered within the normal acceptable range.